banner
Products
Rich expertise and next-generation tools
PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

Overview Package size per unit product 60.00cm * 60.00cm * 0.20cm Gross weight per unit product 1.430kg ESD Vinyl Floori;
Basic Info
Model NO. KM-ESD
Style Modern
Function Anti-Slip, Moisture Proof, Wear-Resistant, Fireproof, Waterproof, Soundproof, Anti-Static, Thermal Insulation
Thickness 2mm 2.5mm 3mm
Lead Hardness Semi-Rigid
Surface Treatment PU
Pattern Stone
Color Multi-Color
State Block
Usage Household, Commercial, Sports, Shopping Mall, Hospital, School, Theatre, Library
OEM Available Yes
Delivery Date 15 Days After Receive 30% T/T Deposit
Transport Packing 1* 20 Gp=6400sqm=40sqm * 16 Rolls * 10 Plts
Static Dissipative Electronic Resistance 1.0X10e6 Ohms - 1.0X10e9 Ohms
Conductive Electronic Resistance <1.0X10e6 Ohms
Fire Resistance Bfl-S1
Weight 3980G/M2 (2.0mm Thickness)
Slip Resistance Wet R9
Stating Voltage 50V for Conductive, 100V for Dissipative
Transport Package Craft Paper + Plastic Pallets
Specification 2mm * 2m * 20m
Trademark OEM
Origin China
HS Code 3918109000
Production Capacity 2000000sqms/Year
Packaging & Delivery
Package size per unit product 60.00cm * 60.00cm * 0.20cm Gross weight per unit product 1.430kg
Product Description

ESD Vinyl Flooring Tiles Anti Static PVC Floor Tiles 600mmx600mmx2mm

Product Description

Electrostatic Discharge (ESD) flooring is also known as anti-static flooring, comes with anti-static performance (static-dissipative or conductive), and protects electronics from damage caused by static electricity.The ESD flooring tiles are of high density, non-porous natural organic tile visual. They're manufactured by an extrusion process, mixing and pressing the pure PVC granules with carbon (graphite) fibers, and non-toxic color particles under proper pressure and temperature. Conductive elements are distributed throughout the flooring material, Thus they give ESD floors electrical conductivity, create an electrical pathway from the walking surface to the ground, and guarantee a permanent ESD performance.

ESD vinyl flooring tiles are the choice of professionals for controlling electrostatic discharge in clean rooms, electronics manufacturing, computer rooms, repair facilities, or anywhere static-sensitive components are being used or manufactured.

ESD Tile Sizes

The popular and standard size is 600×600mm, 610x610mm, 900×900mm.The thickness of the tiles is mainly 2.0mm, 2.5mm, 3.0mm.Weight: 3980g/m2 (2.0mm Thickness)

PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

Detailed Photos


PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

 

Product Parameters

NameESD PVC Floor
Thickness2mm,2.5mm,3mm
MaterialPVC
Use placeClean room,hospital,electronic workshop,etc
Product advantagesWear-resistant,fire-resistant,and waterproof
AccessoriesCopper foil,welding rod,conductive glue
ItemStandardData
Electrical Resistance(Ω)SJ/T11236-2001Conductive Dissipative
2.5 x 10E4 - 1.0 x 10E6 ohms1.0 x 10E6 to 1.0 x 10E9 ohms
Dimensional(%)ISO 23999:20180.05
Stating VoltageSJ/T11236-200150 V100 V
Static Decay(s)GJB2605-1996≤ 2
Wear ResistanceEN 660-2:1999Class P
Fire ResistanceEN13501-1:2007Bfl-s1
Radiant Flux(W/cm2)ASTM E648-2017≥ 1.1
Slip Resistance WetEN13893≥ 0.3
Residual Indentation(mm)ISO 24343-1:2002≤ 0.15-0.03mm
Color FastnessISO 105B 02≥ 6
Chemical Products ResistanceEN ISO 26987:2012OK
Migration of Certain ElementsEN 71-3:2013OK
RoHS Directive(%)EN 623210.003
TVOC After 28 Days(μg/m³)ISO 16000-3< 10 μg/m³

Application


ESD vinyl flooring tiles are the choice of professionals for controlling electrostatic discharge in clean rooms, electronics manufacturing, computer rooms, repair facilities, or anywhere static-sensitive components are being used or manufactured.

PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

Installation Instructions

Installation:
Installation should be carried in accordance with local standards. Subfloor to be smooth, hard, clean and dry prior tolaying.Where applicable the subfloor must incorporate an effective Damp Proof Membrane. The material must be allowed toacclimatize 24 hours before installation in a room temperature of between 18 - 24 degree.

PVC Anti-Static Network Floor Computer Room Conductive ESD Vinyl Tile Flooring 600*600*2mm

 

Floor Install Accessories:

 

Product Advantages

Our Advantages

1. We have full-automated production lines to ensure higher production efficiency.2. We have patents on production process optimization.3. Tempering is a process of heat treatment. We have the longest tempering production lines in China which control dimensional stability effectively.4. We have an independent testing laboratory with appropriate testing instruments and equipment.5. Testing and calibration are performed using USA/EU/JAPAN/CHINA standard methods. So we can produce ESD vinyl flooring products in compliance with different standards.6. We use DOTP plasticizer for ESD PVC flooring.Dioctyl terephthalate commonly abbreviated DOTP or DEHT. It is a non-phthalate plasticizer that is considered safer than ortho-phthalate plasticizers due to its excellent toxicological profile.7. The product does not contain carcinogens such as benzene and heavy metals such as lead.

Company Profile

Kama International Trade & technology co., ltd was founded in 2005, we specializing in laminate, PVC vinyl flooring, SPC flooring, Homogeneous, Heterogeneous pvc floor and Wall Panel. With 2 manufacturing quarters located in Jiangsu and Zhejiang Province, products capacity over 7000000sqms each year. Our products has been exported to more than 50 countries and regions all over the world and get great reputation for our high quality products and very good service.

Send inquiry